PyAutomation DataLogger

The DataLogger persistently records tag values from the CVT into the configured database (SQLite, MySQL, or PostgreSQL). It is built for continuous operation in multi-threaded environments and is orchestrated by the LoggerWorker background thread.

Components

  • DataLogger: Low-level API that performs CRUD on tag definitions and writes time-series values (TagValue).
  • DataLoggerEngine: Thread-safe wrapper used by workers and state machines to call the logger without race conditions.
  • LoggerWorker: Periodically drains the tag queue, writes batches to the database, handles backups for SQLite, and monitors OPC UA client connectivity.
  • DBManager: Supplies connections and health checks; the logger short-circuits writes if connectivity is down.

How It Works

  1. CVT updates enqueue tag changes through TagObserver.
  2. LoggerWorker runs on a fixed period (defaults to the LOGGER_PERIOD environment variable, 10s if unset).
  3. The worker filters tags by segment/manufacturer (if configured) and bulk-inserts records via TagValue.insert_many.
  4. When SQLite grows beyond 1 GB, the worker triggers a backup, vacuums the DB, and resumes logging.

Data Logger Workflow

flowchart TD
    A[CVT Tag Update] -->|TagObserver| B[Tag Queue]
    B -->|Periodic Check| C{LoggerWorker}
    C -->|Every LOGGER_PERIOD| D{DB Connected?}
    D -->|No| E[Reconnect Attempt]
    E -->|Success| D
    E -->|Fail| F[Skip Cycle]
    D -->|Yes| G[Filter by Segment/Manufacturer]
    G -->|Apply Deadband| H{Bulk Insert}
    H -->|Success| I[Database]
    H -->|Fail| J[Log Error]

    subgraph "SQLite Maintenance"
        I -->|Size > 1GB| K[Backup DB]
        K --> L[Vacuum DB]
        L --> M[Clear Historical Tables]
    end

Data Logger Architecture

graph LR
    subgraph "Data Sources"
        CVT[CVT Tags]
    end

    subgraph "Logger Engine"
        DLE[DataLoggerEngine]
        DL[DataLogger]
    end

    subgraph "Worker"
        LW[LoggerWorker]
        Queue[Tag Queue]
    end

    subgraph "Persistence"
        DB[(Database)]
    end

    CVT -->|TagObserver| Queue
    Queue -->|Drain| LW
    LW -->|Thread-safe| DLE
    DLE -->|CRUD Operations| DL
    DL -->|Bulk Insert| DB

Configuring and Using the Logger

from automation import PyAutomation

app = PyAutomation()
app.set_db(db_path="./db/app.db", db_type="sqlite")  # or postgres/mysql
app.set_log(history=True)  # enable history logging
app.run()  # starts LoggerWorker among other services

# Tags created in CVT are automatically registered for logging

Key settings: - LOGGER_PERIOD: Interval (seconds) between logging cycles. - dead_band on tags: Skip writes when changes are below the configured threshold. - display_unit: Used for storage; ensure it matches operator-facing units to keep trends consistent.

Reading Historical Data

DataLogger provides convenience methods to fetch trends and aggregates. Example:

from automation.logger.datalogger import DataLogger

logger = DataLogger()
trend = logger.read_tags(tags=["TankLevel"], start="2024-10-01", end="2024-10-02")

Aggregation helpers (e.g., group_by) return averaged buckets with timestamps normalized to the configured timezone.

Reliability and Maintenance

  • The worker retries database connectivity (reconnect_to_db) and logs critical messages when reconnection succeeds or fails.
  • SQLite installations get automatic backups under db/backups/ when size > 1 GB; historical tables are pruned to keep the DB lean after backup.
  • OPC UA client health is checked each cycle to keep field links alive.

Best Practices

  • Enable history only for tags that need trending; unnecessary logging increases storage and IO.
  • Set meaningful dead_band values for noisy signals to reduce churn.
  • Keep display_unit stable—changing it mid-stream complicates downstream analytics.
  • Prefer batching tag writes (write_tags) if you log from custom code; it mirrors the worker’s efficient path.

Troubleshooting

  • No data written: Verify set_log(history=True) is called and DBManager.check_connectivity() returns True.
  • Deadband drops expected points: Lower the tag’s dead_band or disable it for critical signals.
  • SQLite growth: Check backup folder for recent dumps; ensure the worker has permission to write to db/backups.
  • Stale OPC UA data: Inspect LoggerWorker.check_opcua_connection; reconnect logic depends on clients being registered in OPCUAClientManager.